The normal working pressure range and key points of Roots blower are as follows:
1、 Standard pressure range (universal type)
1. * * Regular work pressure**
-Efficiency range: 39.2~78.4 kPa (0.4~0.8 bar)
-Sustainable operating limit: 98 kPa (1.0 bar)
-* Note: 1 bar ≈ 100 kPa ≈ 1.02 kgf/cm2*
2. Different specifications correspond to different pressures**
|Fan model | Rated pressure | Typical application scenarios|
|------------|----------|---------------------|
|Small (≤ 15kW) | 9.8~49 kPa | Laboratory aeration, small gas delivery|
|Medium sized (18~75kW) | 49~78.4 kPa | Sewage treatment and electroplating tank|
|Large (≥ 90kW) | 78.4~98 kPa | Blast furnace blast and vacuum system|
2、 Abnormal pressure judgment and handling
**Low pressure (<rated value 80)**
-Possible reasons:
Impeller wear (clearance>0.4mm)
Imported filter clogged (pressure difference>5kPa needs to be cleaned)
Pipeline leakage (flange/weld leakage)
-* * Handling measures * *:
Adjust the impeller clearance to 0.2~0.3mm
Replace the filter element (initial pressure difference<2kPa)
**Pressure too high (>rated value)**
-* * Dangerous manifestations * *:
The motor current exceeds the rated value of 10
Bearing temperature>85 ℃
-* * Urgent handling * *:
Immediately open the bypass valve
Check if the outlet valve is closed incorrectly
3、 Special working condition pressure correction
|Working conditions | Pressure adjustment coefficient | Response measures|
|----------------|--------------|--------------------------|
|High temperature gas (>80 ℃) | Reduce by 8 for every 100 ℃ | Choose heat-resistant bearings and coolers|
|Corrosive medium * * | Rating reduction of 15-20 | Switching to stainless steel impeller|
|* * High altitude * * (>1000m) | 9 drops per kilometer | Increase motor power by 10 levels|
4、 Pressure regulation specifications
1. * * Strictly prohibit operation * *:
Control pressure through outlet valve throttling (which may cause overpressure and pipe bursting)
2. * * Correct adjustment method * *:
**Variable frequency speed regulation: For every 5Hz decrease in frequency, the pressure drops by approximately 12
**Bypass reflux * *: Maintain flow rate ≥ 20 rated flow rate
**Multi machine parallel * *: Recommended for large systems (3 or more units require pressure equalization tubes)
5、 Maintain monitoring standards
-* * Daily check * *:
Pressure gauge fluctuation range < ± 5 set value
Valve manual testing every month (jump pressure=1.1 x rated pressure)
-Annual maintenance:
Calibrate pressure sensor (error < ± 2)
Replace gear oil (ISO VG220, moisture content<0.1)
**Note: It is recommended to control the long-term operating pressure at 80-90% of the rated value, which can ensure reliability and extend equipment life (for every 10 pressure drops, the bearing life is extended by 50). Please refer to the equipment nameplate and manufacturer's technical agreement for specific parameters.